Switching Specifications (AC)
Over recommended operating conditions (TA = -40 to 100°C, for HCPL-3120,HCPL-J312 IF(ON) = 7 to 16mA, for
HCNW3120 IF(ON) = 10 to 16mA, VF(OFF) = -3.6 to 0.8 V, VCC = 15 to 30 V, VEE = Ground) unless otherwise specified.
Parameter Symbol
Min. Typ.* Max. Units Test Conditions Fig. Note
Propagation Delay Time
tPLH
0.10 0.30 0.50 µs
to High Output Level
Propagation Delay Time
tPHL
0.10 0.30 0.50 µs
to Low Output Level
Rg = 10 Ω,
Cg = 10 nF,
f = 10 kHz,
Duty Cycle = 50%
10, 11, 16
12, 13,
14, 23
Pulse Width Distortion
PWD
0.3
µs
17
Propagation Delay
Difference Between Any
Two Parts
PDD
-0.35
(tPHL - tPLH)
0.35 µs
35, 36 12
Rise Time
tr
0.1
µs
23
Fall Time
tf
0.1
µs
UVLO Turn On Delay
tUVLO ON
0.8
µs
VO > 5 V, IF = 10 mA 22
UVLO Turn Off Delay
tUVLO OFF
0.6
VO < 5 V, IF = 10 mA
Output High Level Common |CMH|
25
35
kV/µs TA = 25°C,
24
Mode Transient Immunity
IF = 10 to 16 mA,
VCM = 1500 V,
VCC = 30 V
Output Low Level Common |CML|
25
35
kV/µs
Mode Transient Immunity
TA = 25°C,
VCM = 1500 V,
VF = 0 V, VCC = 30 V
13, 14
13, 15
*All typical values at TA = 25°C and VCC - VEE = 30 V, unless otherwise noted.
11