DS1254
BATTERY WARNING TIMING
(VCC = 3.3V 10%, TA = 0C to +70C)
PARAMETER
Battery Test Cycle
Battery Test Pulse Width
Battery Test to BW Active
VCC Valid to BW Valid
SYMBOL
tBTC
tBTPW
tBW
tBPU
MIN
TYP
MAX
UNITS NOTES
24
hour
1
seconds
1
seconds
1
seconds
3
AC TEST CONDITIONS
Output Load:
100pF + 1 TTL Gate
Input Pulse Levels: 0V to 3.0V
Timing Measurement Reference Levels:
Input: 1.5V
Output: 1.5V
Input Pulse Rise and Fall Times: 5ns
Figure 4. Memory Read Cycle Timing (Note 9)
ADDRESS
CE
OE
DQ0–DQ7
tRC
tACC
tCO
tOE
tCOE
tCOE
tOH
tOD
tOD
OUTPUT
DATA VALID
9 of 17