CY7C419/21/25/29/33
Operating Range
Range
Ambient Temperature[2]
Commercial
0°C to + 70°C
Industrial
–40°C to +85°C
Military
–55°C to +125°C
VCC
5V ± 10%
5V ± 10%
5V ± 10%
Electrical Characteristics Over the Operating Range[3]
Parameter
VOH
VOL
VIH
Description
Output HIGH Voltage
Output LOW Voltage
Input HIGH Voltage
VIL
Input LOW Voltage
IIX
Input Leakage Current
IOZ
Output Leakage Current
IOS
Output Short Circuit Current[5]
Test Conditions
VCC = Min., IOH = –2.0 mA
VCC = Min., IOL = 8.0 mA
Com’l
Mil/Ind
GND < VI < VCC
R > VIH, GND < VO < VCC
VCC = Max., VOUT = GND
7C419–10, 15, 30, 40
7C420/1–10, 15, 20, 25, 30, 40, 65
7C424/5–10, 15, 20, 25, 30, 40, 65
7C428/9–10, 15, 20, 25, 30, 40, 65
7C432/3–10, 15, 20, 25, 30, 40, 65
Min.
Max.
Unit
2.4
V
0.4
V
2.0
2.2
Note 4
VCC
V
VCC
0.8
V
–10
+10
µA
–10
+10
µA
–90
mA
Electrical Characteristics Over the Operating Range[3] (continued)
7C419–10
7C421–10
7C425–10
7C429–10
7C433–10
7C419–15
7C421–15
7C425–15
7C429–15
7C433–15
7C420–20
7C421–20
7C424–20
7C425–20
7C428–20
7C429–20
7C433–20
7C420–25
7C421–25
7C424–25
7C425–25
7C429–25
7C432–25
7C433–25
Parameter
Description
Test Conditions
Min. Max. Min. Max. Min. Max. Min. Max. Unit
ICC
Operating Current VCC = Max., Com’l
IOUT = 0 mA Mil/Ind
f = fMAX
ICC1
Operating Current VCC = Max., Com’l
IOUT = 0 mA
F = 20 MHz
85
65
55
100
90
35
35
35
50 mA
80
35 mA
ISB1
Standby Current
All Inputs = Com’l
VIH Min.
Mil/Ind
10
10
10
10 mA
15
15
15
ISB2
Power-Down Current All Inputs > Com’l
VCC –0.2V
Mil/Ind
5
5
5
5 mA
8
8
8
Notes:
2. TA is the “instant on” case temperature.
3. See the last page of this specification for Group A subgroup testing information.
4. VIL (Min.) = –2.0V for pulse durations of less than 20 ns.
5. For test purposes, not more than one output at a time should be shorted. Short circuit test duration should not exceed 30 seconds.
Document #: 38-06001 Rev. *A
Page 3 of 22