IS61LV632A
ISSI ®
WRITE CYCLE SWITCHING CHARACTERISTICS (Over Operating Range)
Symbol
tKC
tKH
tKL
tAS
tSS
tWS
tDS
tCES
tAVS
tAH
tSH
tDH
tWH
tCEH
tAVH
tCFG
Parameter
-4
Min. Max.
Cycle Time
8—
Clock High Time
4—
Clock Low Time
4—
Address Setup Time 2.5 —
Address Status
Setup Time
2.5 —
Write Setup Time
2.5 —
Data In Setup Time
2.5 —
Chip Enable Setup Time 2.5 —
Address Advance
Setup Time
2.5 —
Address Hold Time
0.5 —
Address Status
Hold Time
0.5 —
Data In Hold Time
0.5 —
Write Hold Time
0.5 —
Chip Enable Hold Time 0.5 —
Address Advance
Hold Time
0.5 —
Configuration Setup(1) 25 —
-5
Min. Max.
10 —
4—
4—
2.5 —
2.5 —
2.5 —
2.5 —
2.5 —
2.5 —
0.5 —
0.5 —
0.5 —
0.5 —
0.5 —
0.5 —
35 —
-6
Min. Max.
12 —
4—
4—
2.5 —
2.5 —
2.5 —
2.5 —
2.5 —
2.5 —
0.5 —
0.5 —
0.5 —
0.5 —
0.5 —
0.5 —
45 —
Notes:
1. Configuration signal MODE is static and must not change during normal operation.
-7
Min. Max.
13 —
6—
6—
2.5 —
2.5 —
2.5 —
2.5 —
2.5 —
2.5 —
0.5 —
0.5 —
0.5 —
0.5 —
0.5 —
0.5 —
52 —
-8
Min. Max.
15 —
6—
6—
2.5 —
2.5 —
2.5 —
2.5 —
2.5 —
2.5 —
0.5 —
0.5 —
0.5 —
0.5 —
0.5 —
0.5 —
60 —
Unit
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
10
Integrated Silicon Solution, Inc. — 1-800-379-4774
Rev. A
04/17/01