Timing Diagrams (continued)
Figure 6. ZZ Mode Timing [22, 23]
CY7C1325H
CLK
ZZ
I SUPPLY
A LL INPUTS
(except ZZ)
Outputs (Q)
t ZZ
t ZZI
I DDZZ
t ZZREC
High-Z
DON’T CARE
t RZZI
DESELECT or READ Only
Notes
22. Device must be deselected when entering ZZ mode. See Cycle Descriptions table for all possible signal conditions to deselect the device.
23. DQs are in High Z when exiting ZZ sleep mode.