CY14B101Q1
CY14B101Q2
CY14B101Q3
Software Controlled STORE and RECALL Cycles
Over the Operating Range
Parameter
Description
tRECALL
tSS [18, 19]
RECALL duration
Soft sequence processing time
CY14B101Q1/CY14B101Q2/
CY14B101Q3
Unit
Min
Max
–
200
s
–
100
s
Switching Waveforms
Figure 24. Software STORE Cycle[19]
CS
SCK
SI
RWI
RDY
01 234567
00111100
HI-Z
tSTORE
Figure 25. Software RECALL Cycle[19]
CS
SCK
SI
RWI
RDY
01 234567
011
00000
tRECALL
HI-Z
Figure 26. AutoStore Enable Cycle
CS
SCK
SI
RWI
RDY
01234567
0101100 1
tSS
HI-Z
Figure 27. AutoStore Disable Cycle
CS
SCK
SI
RWI
RDY
01 234567
00011001
tSS
HI-Z
Notes
18. This is the amount of time it takes to take action on a soft sequence command. Vcc power must remain HIGH to effectively register command.
19. Commands such as STORE and RECALL lock out I/O until operation is complete which further increases this time. See the specific command.
Document Number: 001-50091 Rev. *L
Page 19 of 27