CXA2164Q
Decoder Output and Mode Control Table 2 (SAPC = 0)
Input signal mode
MONO ∗1
STEREO ∗1
MONO & SAP
STEREO & SAP
Mode detection
Mode control
ST
SAP NOISE NRSW FOMO SAPC
0
0
∗
∗
∗
0
0
1
1
0
0
0
0
1
1
0
1
0
0
1
1
1
0
0
0
1
1
1
1
0
1
0
∗
0
0
0
1
0
∗
0
1
0
1
0
∗
1
0
0
1
0
∗
1
1
0
1
1
1
0
0
0
1
1
1
0
1
0
1
1
1
1
0
0
1
1
1
1
1
0
0
1
0
0
0
0
0
1
0
0
1
0
0
1
0
1
0
0
0
1
0
1
1
0
0
1
1
0
0
0
0
1
1
0
1
0
0
1
1
1
0
0
0
1
1
1
1
0
1
1
0
0
0
0
1
1
0
0
1
0
1
1
0
1
0
0
1
1
0
1
1
0
1
1
1
0
0
0
1
1
1
0
1
0
1
1
1
1
0
0
1
1
1
1
1
0
dbx
input
MUTE
MUTE
MUTE
(SAP)
(SAP)
L–R
MUTE
L–R
MUTE
L–R
MUTE
(SAP)
(SAP)
MUTE
MUTE
SAP
SAP
MUTE
MUTE
(SAP)
(SAP)
L–R
MUTE
SAP
SAP
L–R
MUTE
(SAP)
(SAP)
Output
Lch
L+R
Rch
L+R
L+R L+R
L+R L+R
(SAP) (SAP)
L + R (SAP)
L
R
L+R L+R
L
R
L+R L+R
L
R
L+R L+R
(SAP) (SAP)
L + R (SAP)
L+R L+R
L+R L+R
SAP SAP
L + R SAP
L+R L+R
L+R L+R
(SAP) (SAP)
L + R (SAP)
L
R
L+R L+R
SAP SAP
L + R SAP
L
R
L+R L+R
(SAP) (SAP)
L + R (SAP)
Note
(SAP) : The SAPOUT output signal is soft muted (approximately –7dB).
The signal is soft muted when NOISE = 1.
∗ : Don’t care.
∗1 SAP or NOISE discrimination may be made during MONO or STEREO input when the noise is
inputted in the weak electric field.
Then microcomputer reads "NOISE" status from IC and decides whether SAP is outputted.
"NOISE" status rises earlier than "SAP" status when the amount of noise is increased to COMPIN.
– 20 –