ABSOLUTE MAXIMUM RATINGS*
(TA = 25∞C, unless otherwise noted.)
VDD to GND . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +7 V
PWRGND to AGND . . . . . . . . . . . . . . –20 mV to +20 mV
Analog Input Voltage to GND . . . . . –0.3 V to VDD + 0.3 V
Reference Input Voltage to GND . . . –0.3 V to VDD + 0.3 V
Total AIN/REFIN Current (Indefinite) . . . . . . . . . . 30 mA
Digital Input Voltage to GND . . . . . . . –0.3 V to VDD + 0.3 V
Digital Output Voltage to GND . . . . –0.3 V to VDD + 0.3 V
Operating Temperature Range . . . . . . . . . . –40∞C to +85∞C
Storage Temperature Range . . . . . . . . . . . . –65∞C to +150∞C
Junction Temperature . . . . . . . . . . . . . . . . . . . . . . . . . 150∞C
qJA Thermal Impedance . . . . . . . . . . . . . . . . . . . 97.9∞C/W
qJC Thermal Impedance . . . . . . . . . . . . . . . . . . . . . 14∞C/W
Lead Temperature, Soldering
Vapor Phase (60 sec) . . . . . . . . . . . . . . . . . . . . . . . . 215∞C
Infrared (15 sec) . . . . . . . . . . . . . . . . . . . . . . . . . . . 220∞C
*Stresses above those listed under Absolute Maximum Ratings may cause perma-
nent damage to the device. This is a stress rating only; functional operation of the
device at these or any other conditions above those listed in the operational
sections of this specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device reliability.
PIN CONFIGURATION
IOUT1 1
24 XTAL1
IOUT2 2
23 XTAL2
REFIN1(+) 3
REFIN1(–) 4
22 VDD
21 GND
AIN1 5 AD7709 20 DIN
AIN2 6 TOP VIEW 19 DOUT
AIN3/P3 7 (Not to Scale) 18 RDY
AIN4/P4 8
17 CS
AINCOM 9
16 SCLK
REFIN2(+) 10
15 RESET
REFIN2(–) 11
14 P1/SW1
P2/SW2 12
13 PWRGND
ORDERING GUIDE
Model
AD7709ARU
AD7709BRU
EVAL-AD7709EB
Temperature
Range
–40∞C to +85∞C
–40∞C to +85∞C
Package
Description
TSSOP
TSSOP
Evaluation Board
Package
Option
RU-24
RU-24
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although the
AD7709 features proprietary ESD protection circuitry, permanent damage may occur on devices
subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are recommended
to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE
–8–
REV. A