6818
32-BIT SERIAL-INPUT,
LATCHED SOURCE DRIVER
TIMING REQUIREMENTS and SPECIFICATIONS
(Logic Levels are VDD and Ground)
C
CLOCK
50%
SERIAL
DATA IN
SERIAL
DATA OUT
A
B
DATA
50%
t p(CH-SQX)
50%
D
E
DATA
STROBE
50%
BLANKING
OUT N
LOW = ALL OUTPUTS ENABLED
t p(STH-QH)
t p(STH-QL)
90%
DATA
10%
BLANKING
OUT N
Dwg. WP-029
HIGH = ALL OUTPUTS BLANKED (DISABLED)
50%
t en(BQ)
t dis(BQ)
tr
DATA
10%
tf
90%
50%
A. Data Active Time Before Clock Pulse
(Data Set-Up Time), tsu(D) ......................................... 25 ns
B. Data Active Time After Clock Pulse
(Data Hold Time), th(D) ............................................... 25 ns
C. Clock Pulse Width, tw(CH) ............................................... 50 ns
D. Time Between Clock Activation and Strobe, tsu(C) ....... 100 ns
E. Strobe Pulse Width, tw(STH) ............................................. 50 ns
NOTE – Timing is representative of a 10 MHz clock. Signifi-
cantly higher speeds are attainable.
Serial Data present at the input is transferred to the shift
register on the logic “0” to logic “1” transition of the CLOCK
input pulse. On succeeding CLOCK pulses, the registers shift
data information towards the SERIAL DATA OUTPUT. The
SERIAL DATA must appear at the input prior to the rising edge
of the CLOCK input waveform.
Dwg. WP-030A
Information present at any register is transferred to the
respective latch when the STROBE is high (serial-to-parallel
conversion). The latches will continue to accept new data as
long as the STROBE is held high. Applications where the
latches are bypassed (STROBE tied high) will require that the
BLANKING input be high during serial data entry.
When the BLANKING input is high, the output source
drivers are disabled (OFF); the pnp active pull-down sink
drivers are ON. The information stored in the latches is not
affected by the BLANKING input. With the BLANKING input
low, the outputs are controlled by the state of their respective
latches.