74VHC373
DYNAMIC SWITCHING CHARACTERISTICS
Symb ol
Parameter
Test Conditions
V CC
( V)
Value
TA = 25 oC
Min. Typ. Max.
-40 to 85 oC
Min . Max.
Un it
VOLP Dynamic Low Voltage
5.0
VOLV Quiet Output (note 1, 2)
0.6 0.9
-0.9 -0.6
VIHD Dynamic High Voltage
5.0
CL = 50 pF
3.5
V
Input (note 1, 3)
VILD Dynamic Low Voltage
5.0
1.5
Input (note 1, 3)
1) Worst case package.
2) Max number of outputs defined as (n). Data inputs are driven 0V to 5.0V, (n -1) outputs switching and one output at GND.
3) Max number of data inputs (n) switching. (n-1) switching 0V to5.0V. Inputs under test switching: 5.0V to threshold (VILD), 0V to threshold (VIHD), f=1MHz.
TEST CIRCUIT
TEST
tPLH, tPHL
tPZL, tPLZ
tPZH, tPHZ
CL = 15/50 pF or equivalent (includes jig and probe capacitance)
RL = R1 = 1KΩ orequivalent
RT = ZOUT of pulse generator (typically 50Ω)
SW IT CH
Open
VCC
GND
5/10