M54/M74HC4051/4052/4053
RECOMMENDED OPERATING CONDITIONS
Symbol
VCC
VEE
VCC - VEE
VIN
VI/O
Top
tr, tf
Parameter
Supply Voltage
Supply Voltage
Supply Voltage
Input Voltage
Input/Output Voltage
Operating Temperature: M54HC Series
M74HC Series
Input Rise and Fall Time
VCC = 2 V
VCC = 4.5 V
VCC = 6 V
Value
2 to 6
-6 to 0
2 to 12
0 to VCC
VEE to VCC
-55 to +125
-40 to +85
0 to 1000
0 to 500
0 to 400
Unit
V
V
V
V
V
oC
oC
ns
DC SPECIFICATIONS
Symbol Parameter
VIHC High Level
Control Input
Voltage
VILC Low Level
Control Input
Voltage
RON ON Resistance
∆RON
Difference of
ON Resistance
Between
Switches
Test Conditions
VCC VEE
(V) (V)
TA = 25 oC
54HC and 74HC
Value
-40 to 85 oC -55 to 125 oC Unit
74HC
54HC
Min. Typ. Max. Min. Max. Min. Max.
2.0
1.5
1.5
1.5
4.5
3.15
3.15
3.15
V
6.0
4.2
4.2
4.2
2.0
0.5
0.5
0.5
4.5
1.35
1.35
1.35 V
6.0
1.8
1.8
1.8
4.5 GND VIN = VIHC or VILC
85 180
225
270
4.5 -4.5 VI/O = VCC to VEE
55 120
150
180
6.0 -6.0
II/O ≤ 2 mA
50 100
125
150 Ω
2.0 GND VIN = VIHC or VILC
150
4.5 GND VI/O = VCC or VEE
70 150
190
230
4.5 -4.5
II/O ≤ 2 mA
50 100
125
150
6.0 -6.0
45 80
100
120
4.5 GND VIN = VIHC or VILC
10 30
35
45
4.5 -4.5 VI/O = VCC or VEE
5 12
15
18 Ω
6.0 -6.0 II/O ≤ 2 mA
5 10
12
15
IOFF Input/Output
6.0 GND VOS = VCC or
Leakage
GND
Current
6.0 -6.0 VIS = GND or VCC
(SWITCH OFF)
VIN = VILC or VIHC
IIZ Switch Input
6.0 GND VOS = VCC or
Leakage Current
GND
(SWITCH ON,
6.0 -6.0 VIN = VIHC or VILC
OUTPUT OPEN)
IIN Control Input
Current
6.0 GND VIN = VCC or GND
ICC
Quiescent
Supply Current
6.0 GND VIN = VCC or GND
6.0 -6.0
±0.06
±0.6
±0.1
±1
±0.06
±0.6
±0.1
±1
±0.1
±0.1
4
40
8
80
±1.2
±2 µA
±1.2
±2 µA
±1 µA
80 µA
160
6/15