Status output
R ST(ON)
+5V
ST
BTS612N1
Open-load detection
OFF-state diagnostic condition: VOUT > 3 V typ.; IN low
GND
ESD-
ZD
ESD-Zener diode: 6.1 V typ., max 5 mA;
RST(ON) < 380 at 1.6 mA, ESD zener diodes are not
to be used as voltage clamp at DC conditions.
Operation in this mode may result in a drift of the zener
voltage (increase of up to 1 V).
OFF
I L(OL)
Logic
unit
Open load
detection
V OUT
Inductive and overvoltage output clamp
+ Vbb
VZ
VON
OUT
GND
PROFET
VON clamped to 47 V typ.
Signal GND
GND disconnect
Vbb
3 IN1
6 IN2
ST
5
VIN1VIN2
V
ST
Ibb
4
Vbb
PROFET
1
OUT1
GND
OUT2
7
2
V
GND
Overvolt. and reverse batt. protection
+ Vbb
RI
IN1
IN2
ST
R ST
VZ1
VZ2
Logic
R GND
GND
Signal GND
VZ1 = 6.1 V typ., VZ2 = 47 V typ., RI= 3.5 k typ
RGND= 150
Any kind of load. In case of Input=high is VOUT VIN - VIN(T+) .
Due to VGND >0, no VST = low signal available.
GND disconnect with GND pull up
3 IN1
VIN1
6 IN2
VIN2
ST
5
4
Vbb
PROFET
1
OUT1
GND
OUT2
7
2
Vbb
VST
VGND
Any kind of load. If VGND > VIN - VIN(T+) device stays off
Due to VGND >0, no VST = low signal available.
Data Sheet
8
2013-10-11