datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

MAX1026(2003) View Datasheet(PDF) - Maxim Integrated

Part Name
Description
MFG CO.
MAX1026 Datasheet PDF : 24 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
10-Bit 300ksps ADCs with FIFO,
Temp Sensor, Internal Reference
Pin Description
MAX1030
QFN
MAX1030
QSOP
MAX1028
MAX1026
NAME
FUNCTION
1, 17, 19,
25
N.C.
No Connection. Not internally connected.
212, 26,
27, 28
114
AIN013 Analog Inputs
110
AIN09 Analog Inputs
16
AIN05 Analog Inputs
13
15
REF-/AIN14 Negative Input for External Differential Reference/Analog Input 14.
See Table 3 for details on programming the setup register.
11
REF-/AIN10
Negative Input for External Differential Reference/Analog Input 10.
See Table 3 for details on programming the setup register.
7
REF-/AIN6 Negative Input for External Differential Reference/Analog Input 6.
See Table 3 for details on programming the setup register.
14
16
CNVST/ Active-Low Conversion Start Input/Analog Input 15. See Table 3
AIN15 for details on programming the setup register.
12
CNVST/ Active-Low Conversion Start Input/Analog Input 11. See Table 3
AIN11 for details on programming the setup register.
8
CNVST/ Active-Low Conversion Start Input/Analog Input 7. See Table 3 for
AIN7
details on programming the setup register.
15
17
13
9
REF+
Positive Reference Input. Bypass to GND with a 0.1µF capacitor.
16
18
14
10
GND
Ground
18
19
15
11
VDD
Power Input. Bypass to GND with a 0.1µF capacitor.
Serial Clock Input. Clocks data in and out of the serial interface.
20
20
16
12
SCLK
(Duty cycle must be 40% to 60%.) See Table 3 for details on
programming the clock mode.
21
21
17
13
CS
Active-Low Chip-Select Input. When CS is low, the serial interface
is enabled. When CS is high, DOUT is high impedance.
22
22
18
14
DIN
Serial Data Input. DIN data is latched into the serial interface on
the rising edge of SCLK.
23
23
19
15
DOUT
Serial Data Output. Data is clocked out on the falling edge of
SCLK. High impedance when CS is connected to VDD.
24
24
20
16
EOC
End of Conversion Output. Data is valid after EOC pulls low.
8 _______________________________________________________________________________________