3195
PROTECTED, HIGH-TEMP.,
ACTIVE PULL-DOWN
HALL-EFFECT LATCH
TYPICAL OPERATING CHARACTERISTICS
200
OPERATE POINT
100
0
VCC = 3.8 V–26 V
-100
RELEASE POINT
-200
-50
-25
0
25
50
75
100
125
150
AMBIENT TEMPERATURE IN °C
Dwg. GH-052-1
Vcc
Vcc - 1
OUTPUT HIGH, B ≤ B RP
(SOURCING CURRENT)
IOUT = -20 mA
Vcc - 2
0.4
VCC = 16 V
IOUT = 5 mA
0.2
OUTPUT LOW, B ≥ B OP
(SINKING CURRENT)
I OUT ≤ 100 µA
0
-50
-25
0
25
50
75
100
AMBIENT TEMPERATURE IN °C
125
150
Dwg. GH-040-2
TYPICAL OPERATING CHARACTERISTICS
Output Current Limit
20
9.0
OUTPUT LOW, B ≥ B OP
(SINKING CURRENT)
0
8.0
VCC = 26 V
-20
VCC = 16 V
-40
OUTPUT HIGH, B ≤ B RP
(SOURCING CURRENT)
-60
-50
-25
0
25
50
75
100
125
150
AMBIENT TEMPERATURE IN °C
Dwg. GH-004-1
7.0
VCC = 12 V
6.0
VCC = 3.8 V
5.0
-50
OUTPUT HIGH, B ≥ B OP
OUTPUT LOW, B ≤ B RP
-25
0
25
50
75
100
AMBIENT TEMPERATURE IN °C
125 150
Dwg. GH-028-2
115 Northeast Cutoff, Box 15036
Worcester, Massachusetts 01615-0036 (508) 853-5000