SWITCHING SPECIFICATIONS (AVDD = +5 V, DVDD = +5 V, CL = 20 pF, TMIN to TMAX unless otherwise noted)
Parameters
Symbol
AD9260
Clock Period
Data Available (DAV) Period
Data Invalid
Data Setup Time
Clock Pulsewidth High
Clock Pulsewidth Low
Data Hold Time
RESET to DAV Delay
CLOCK to DAV Delay
Three-State Output Disable Time
Three-State Output Enable Time
tC
tDAV
tDI
tDS
tCH
tCL
tH
tRESDAV
tCLKDAV
tOD
tOE
50
tC × Mode
40% tDAV
tDAV tHtDI
22.5
22.5
3.5
10
15
8
45
Specifications subject to change without notice.
Units
ns min
ns min
ns max
ns min
ns min
ns min
ns min
ns typ
ns typ
ns typ
ns typ
ABSOLUTE MAXIMUM RATINGS*
ORDERING GUIDE
Parameter
With
Respect
to
Min
AVDD
AVSS 0.3
DVDD
DVSS 0.3
AVSS
DVSS 0.3
AVDD
DVDD 6.5
DRVDD
DRVSS 0.3
DRVSS
AVSS 0.3
REFCOM
AVSS 0.3
CLK, MODE, READ,
CS, RESET
DVSS 0.3
Digital Outputs
DRVSS 0.3
VINA, VINB,
CML, BIAS
AVSS 0.3
VREF
AVSS 0.3
SENSE
AVSS 0.3
CAPB, CAPT
AVSS 0.3
Junction Temperature
Storage Temperature
65
Lead Temperature
(10 sec)
Max
+6.5
+6.5
+0.3
+6.5
+6.5
+0.3
+0.3
Units
V
V
V
V
V
V
V
DVDD + 0.3 V
DRVDD + 0.3 V
AVDD + 0.3 V
AVDD + 0.3 V
AVDD + 0.3 V
AVDD + 0.3 V
+150
°C
+150
°C
+300
°C
*Stresses above those listed under Absolute Maximum Ratings may cause perma-
nent damage to the device. This is a stress rating only; functional operation of the
device at these or any other conditions above those indicated in the operational
sections of this specification is not implied. Exposure to absolute maximum ratings
for extended periods may effect device reliability.
Model
AD9260AS
AD9260EB
Temperature
Range
40°C to +85°C
Package
Description
Package
Option*
44-Lead MQFP S-44
Evaluation Board
*S = Metric Quad Flatpack.
THERMAL CHARACTERISTICS
Thermal Resistance
44-Lead MQFP
θJA = 53.2°C/W
θJC = 19°C/W
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection.
Although the AD9260 features proprietary ESD protection circuitry, permanent damage may
occur on devices subjected to high-energy electrostatic discharges. Therefore, proper ESD
precautions are recommended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE
REV. B