Smart battery protection and monitoring IC
M61040FP
3. Absolute Maximum Ratings
Table 3
ITEM
SYMBOL
CONDITION
Absolute maximum rating
Vabs
Supply voltage
Vcc
Power dissipation
PD
Operating temperature range
Topr1
Storage temperature range
Tstg
RATINGS
33
30
750
− 20 ∼ + 85
− 40 ∼ + 125
UNIT
V
V
mW
°C
°C
4.Electrical Characteristics
ITEM
SYMBOL
Table 4
CONDITION
(Ta=25°C VCC=14V ,unless otherwise noted)
M i n . T y p . M a x . UNIT Circuit
Supply voltage
Vcc
30
V
Supply current 1
Isup1
Voltage monitor ,V/R, reset ON
Current monitor O N
105
200
280
µA 7
Supply current 2
Voltage monitor ,V/R, reset ON
Isup2 Current monitor OFF
65
120
165
µA 7
Supply current
(at Power save mode)
Ips
Regulator ON, Non-loading,
Reset circuit ON, Others OFF
35
60
85
µA 7
Supply current
(at Power Down mode)
Ipd All operation stop, VI N 12=GND
0.5
µA 7
Output voltage
Vreg Iout=20mA
5.145 5.2 5.295 V 3
Input and output voltage
Difference
Linear regulation
Load regulation
Input voltage
Vdif0 Iout=20mA
∆Vout10
∆Vout20
VIN 0
VCC=6.2∼ 24V Iout=20mA
VCC=6.2V Iout=50µA∼ 20mA
VCC voltage
0.3
0.8
V3
100 200 m V 3
30
45
mV 3
30
V
Output voltage
Vref Iout=200µA
4.818 4.85 4.917 V 4
Load stability
∆Vout21 VCC=6.2V Iout=50∼ 200µA
5
45
mV 4
Over current inhibit
Detection voltage 1
Over current inhibit
detection voltage 2
Over current inhibit
detection delay time1
Over current inhibit
detection delay time 2
Vcl
Vch
Tvcl
Tvch
Load short detection
CICT=0.01µF
VCL− 0.02 0.2 VCL+ 0.02 V 8
VCC
3
×0.6
VCC
3
VCC
3
×1.4
V
8
7
10
15
mse
c
5
150 250 350 µsec 8
Mitsubishi Electric
(6/25)