datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

SY100H641 View Datasheet(PDF) - Micrel

Part Name
Description
MFG CO.
SY100H641 Datasheet PDF : 6 Pages
1 2 3 4 5 6
Micrel, Inc.
Precision Edge®
SY10H641
SY100H641
10H ECL DC ELECTRICAL CHARACTERISTICS
VT = VE = 5.0V ± 5%
TA = 0°C
TA = +25°C
TA = +85°C
Symbol
Parameter
Min.
Max.
Min.
Max.
Min.
Max. Unit
IIH
Input HIGH Current
225
175
175
µA
IIL
Input LOW Current
0.5
0.5
0.5
µA
VIH
Input HIGH Voltage(1)
3.830 4.160 3.870 4.190 3.940 4.280 V
VIL
Input LOW Voltage(1)
3.050 3.520 3.050 3.520 3.050 3.555 V
VBB
Output Reference Voltage(1)
3.620 3.730 3.650 3.750 3.690 3.810 V
Note:
1. VIH, VIL and VBB are referenced to VE and will vary 1:1 with the power supply. The levels shown are for VE = +5.0V.
Condition
VE = 5.0V
VE = 5.0V
VE = 5.0V
100H ECL DC ELECTRICAL CHARACTERISTICS
VT = VE = 5.0V ± 5%
TA = 0°C
TA = +25°C
TA = +85°C
Symbol
Parameter
Min. Max.
Min. Max. Min. Max. Unit
IIH
Input HIGH Current
225
175
175
µA
IIL
Input LOW Current
VIH
Input HIGH Voltage(1)
0.5
0.5
0.5
µA
3.835 4.120 3.835 4.120 3.835 4.120
V
VIL
Input LOW Voltage(1)
3.190 3.525 3.190 3.525 3.190 3.525
V
VBB
Output Reference Voltage(1)
3.620 3.740 3.620 3.740 3.620 3.740
V
Note:
1. VIH, VIL and VBB are referenced to VE and will vary 1:1 with the power supply. The levels shown are for VE = +5.0V.
Condition
VE = 5.0V
VE = 5.0V
VE = 5.0V
AC ELECTRICAL CHARACTERISTICS
VT = VE = 5.0V ± 5%
TA = 0°C
TA = +25°C
TA = +85°C
Symbol
Parameter
Min. Max. Min. Max. Min. Max. Unit
Condition
tPD
tskpp
tskew++
tskew– –
tPLH
tPHL
tPLH
tPHL
tr
tf
fMAX
Propagation Delay
D to Output
Part-to-Part Skew(1,4)
Within-Device Skew(2,4)
Within-Device Skew(3,4)
Propagation Delay
LEN to Output
Propagation Delay
EN to Output
Output Rise/Fall Time
0.8V to 2.0V
Maximum Input Frequency(5,6)
Pulse Width
Recovery Time
5.0
6.0
4.8 5.8
5.3
6.3
ns
1.0
— 1.0
1.0
ns
0.5
— 0.5
0.5
ns
0.5
— 0.5
0.5
ns
4.9
6.9
4.9 6.9
5.0
7.0
ns
5.0
7.0
4.9 6.9
5.0
7.0
ns
1.7
— 1.7
1.7
ns
1.6
— 1.6
1.6
135
135 —
135
— MHz
1.5
1.5 —
1.5
ns
1.25 — 1.25 — 1.25 —
ns
CL = 50pF
CL = 50pF
CL = 50pF
CL = 50pF
CL = 50pF
CL = 50pF
CL = 50pF
CL = 50pF
tS
Set-up Time
tH
Hold Time
0.5 (typ.)
0.5 (typ.)
0.5 (typ.)
ns
0.5 (typ.)
0.5 (typ.)
0.5 (typ.)
ns
Notes:
1. Device-to-Device Skew considering HIGH-to-HIGH transitions at common
power supply voltage.
2. Within-Device Skew considering HIGH-to-HIGH transitions at common
power supply voltage.
3. Within-Device Skew considering LOW-to-LOW transitions at common
power supply voltage.
4. All skew parameters are guaranteed but not tested.
5. Frequency at which output levels will meet a 0.8V to 2.0V minimum swing.
6. The fMAX value is specified as the minimum guaranteed maximum
frequency. Actual operational maximum frequency may be greater.
M9999-032906
hbwhelp@micrel.com or (408) 955-1690
4