Micrel
ABSOLUTE MAXIMUM RATINGS(1)
Symbol
Rating
VE (ECL)
VT (TTL)
Power Supply
Voltage
VI (ECL)
VOUT (TTL)
IOUT (ECL)
Tstore
TA
Input Voltage
Disabled 3-State
Output
Output Current
- Continuous
- Surge
Storage Temperature
Operating Temperature
NOTE:
1. Do not exceed.
Value
–0.5 to +7.0
–0.5 to +7.0
0.0 to VEE
0.0 to VCCT
50
100
–65 to +150
0 to +85
Unit
V
V
V
mA
˚C
˚C
TRUTH TABLE
D
LEN
L
L
H
L
X
H
X
X
ClockWorks™
SY10H641
SY100H641
EN
Q
L
L
L
H
L
Q0
H
L
VCC AND CLOAD
Ranges to meet duty cycle requirement: 0°C ≤ TA ≤ 85°C. Output duty cycle measured relative to 1.5V.
Symbol
Parameter
Min. Typ. Max.
Unit
Condition
PW1
Ranges of VCC and CL to meet min.
VCC
4.75
5.0
5.25
V
pulse width (HIGH or LOW) at
CL
10
—
50
pF
fOUT ≤ 40MHz
PW
11
—
—
ns
PW2
Ranges of VCC and CL to meet min.
VCC 4.875 5.0
5.125
V
pulse width (HIGH or LOW) at
CL
15
—
27
pF
fOUT ≤ 50MHz
PW
9.0
—
—
ns
All Outputs
All Outputs
DC ELECTRICAL CHARACTERISTICS
VT = VE = 5.0V ± 5%
Symbol
Parameter
TA = 0°C
TA = +25°C
TA = +85°C
Min. Max. Min. Max. Min. Max. Unit
IEE
ICCH
ICCL
Power Supply Current
ECL
—
30
—
30
—
30
mA
TTL
—
30
—
30
—
30
—
35
—
35
—
35
Condition
VE Pin
Total all VT pins
TTL DC ELECTRICAL CHARACTERISTICS
VT = VE = 5.0V ± 5%
Symbol
VOH
VOL
IOS
Parameter
Output HIGH Voltage
Output LOW Voltage
Output Short Circuit Current
TA = 0°C
Min. Max.
2.0
—
—
0.5
–100 –225
TA = +25°C
Min. Max.
2.0
—
—
0.5
–100 –225
TA = +85°C
Min. Max.
2.0
—
—
0.5
–100 –225
Unit
V
V
mA
Condition
IOH = –15mA
IOL = 24mA
VOUT = 0V
2