Features
• Automotive applications
• Standardized terminal size & layout
• Now with continuous current capacity to 80 amps !
• Plastic cover for enviromental protection
NRowatiwngiths &ImMproouvnetding Options !
G41
Characteristics
• Operate / Release Time: 7ms / 2 ms typical
• Dielectric Strength: 500 Vrms, 1 minute
• Insulation Resistance: 100M @ 500 VDC, 50% RH
• Shock Resistance: 20g, 11ms
• Vibration Resistance: 10-40Hz, 1.27mm DA
40-70Hz, 5g
70-100Hz, 0.5mm DA
100-500Hz, 10g
• Drop Resistance: 1M drop ( 6 axii ) to concrete in final enclosure (GM)
• Power Consumption: 1.6W, unsuppressed ; 1.81W w/68 resistor
• Ambient temperature: -40 C to +125 C operating
-40 C to +155 C storage
• Weight: 31g, approx.
Typical Applications :Head Lights, Fog Lamps
Blower Control, Horn,
Power Windows, Fans,
Starters, ABS Systems
n Contact Data
Model
G4130
G4160
Contact Arrangement
Max. Switching Current (M/B)
Contact Material
Max. Switching V
Max. Continuous Current
Minimum Load ( reference)
Mechanical Life
Electrical Life
1 Form A ; 1 Form C
Form A: 120A/40A
Form C: NC45A, NO120A
AgNi
See Curve #1, Current Dependent
Form A: 30A
Form C: NO30A/ NC30A
0.1A, 12VDC
10,000,000 ops.
200,000 ops. ( See Note 4)
1 Form A ; 1 Form C
Form A: 120A/60A
Form C: NC45A, NO120A
AgCdO
See Curve #1, Current Dependent
Form A: 60A
Form C: NO60A/ NC40A
0.5A, 12VDC
10,000,000 ops.
200,000 ops. ( See Note 4)
G4180
1 Form A; 1 Form C
Form A : 240A/80A
Form C: NO240A/NC180A
AgSnOInO
See Curve #2, Current Dependent
Form A : 80A
Form C : NO 80A / NC 60A
0.5A, 12VDC
10,000,000 ops.
200,000 ops. ( See Note 4 )
n
Coil Data
Nominal
Voltage
6
12
24
Coil Resistance
10%
22
90
330
Pull-In
Voltage
3.6
7.2
14.3
Drop-Out
Voltage
0.6
1.2
2.4
Useful Curves
Power Load Limit of G4130. G4160
Power Load Limit of G4180
Switching Voltage (VDC)
Switching Voltage (VDC)
65 SHARK RIVER ROAD, NEPTUNE, NEW JERSEY 07753-7423 USA
TOLL FREE (732) 922-8330 FX (732) 922-6363 E-mail: globalcomponents@msn.com
600R1