M54/M74HC173
AC ELECTRICAL CHARACTERISTICS (CL = 50 pF, Input tr = tf = 6 ns)
Symbol
Parameter
Test Conditions
VCC CL
(V) (pF)
TA = 25 oC
54HC and 74HC
Value
-40 to 85 oC -55 to 125 oC Unit
74HC
54HC
Min. Typ. Max. Min. Max. Min. Max.
tREM Minimum
Removal Time
2.0
4.5 50
5
5
5
5
5
5
ns
6.0
5
5
5
CIN Input Capacitance
5
10
10
10 pF
CPD (*) Power Dissipation
50
Capacitance
pF
(*) CPD is defined as the value of the IC’s internal equivalent capacitance which is calculated from the operating current consumption without load.
(Refer to Test Circuit). Average operting current can be obtained by the following equation. ICC(opr) = CPD •VCC •fIN + ICC/4 (per circuit)
SWITCHING CHARACTERISTICS TEST WAVEFORM
EACH FLIP-FLOP SHALL BE SET HIGH WHEN
SWITCH IS CONNECTED TO GND LINE AND
IT SHALL BE SET LOW WHEN SWITCH IS
6/12