M54/M74HC242/243
TEST CIRCUIT ICC (Opr.)
CCP CALCULATION
CPD is to be calculated with the following formula
by using the measured value of ICC (Opr.) in the
test circuit opposite
CPD
=
ICC
fIN
(Opr.)
x VCC
In determining the typical value of CPD, a
relatively high frequency of 1MHz was applied to
fIN, in order to eliminate any error caused by the
quiescent supply current.
6/11