M54/M74HCT240PU/241PU/244PU
RECOMMENDED OPERATING CONDITIONS
Symbol
VCC
VI
VO
Top
tr, tf
Parameter
Supply Voltage
Input Voltage
Output Voltage
Operating Temperature: M54HC Series
M74HC Series
Input Rise and Fall Time (VCC = 4.5 to 5.5V)
Value
4.5 to 5.5
0 to VCC
0 to VCC
-55 to +125
-40 to +85
0 to 500
Unit
V
V
V
oC
oC
ns
DC SPECIFICATIONS
Symbol
VIH
VIL
VOH
VOL
IIL
IIN
IOZ
ICCH
∆ICC
Parameter
High Level Input
Voltage
Low Level Input
Voltage
High Level
Output Voltage
Low Level Output
Voltage
Input Low Current
input Leakage
Current (EN inp.)
3 State Output
Off State Current
Quiescent Supply
Current
Additional worst
case supply
current
Test Conditions
VCC
(V)
TA = 25 oC
54HC and 74HC
Min. Typ. Max.
4.5
2.0
to
5.5
4.5
0.8
to
5.5
VI = IO=-20 µA 4.4
4.5
VIH
or IO=-6.0 mA 4.18
VIL
4.5
4.31
VI = IO= 20 µA
4.5
VIH
or IO= 6.0 mA
VIL
0.0 0.1
0.17 0.26
4.5
VI = 0.4 V
5.5
-50 -130 -250
-50 -180 -300
5.5 VIN = VCC or GND
±0.1
5.5 VIN = VIH or VIL
VO = VCC or GND
5.5
VI = VCC
±0.5
200 600
5.5 Per Input pin
3.0
VI = 0.5V or 2.4V
Other Inputs at
VCC or GND
Value
-40 to 85 oC -55 to 125 oC
74HC
54HC
Min. Max. Min. Max.
2.0
2.0
0.8
0.8
4.4
4.4
4.13
4.10
0.1
0.1
0.33
0.4
-30 -350 -20 -400
-30 -400 -20 -450
±1.0
±1.0
±5.0
±10
800
1000
3.9
4.0
Unit
V
V
V
V
mA
µA
µA
µA
mA