datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

HT6240-002(1999) View Datasheet(PDF) - Holtek Semiconductor

Part Name
Description
View to exact match
HT6240-002
(Rev.:1999)
Holtek
Holtek Semiconductor Holtek
HT6240-002 Datasheet PDF : 14 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
HT6240-002
CT will send at least three words if we press a
legal key. CT may send three or four words, or
several words depending on the length of time
the legal key is pressed. (see Fig. 12)
Power on reset function (PRB)
The power on reset function can be activated by
connecting a capacitor to PRB pin while power
is applied. The time (tC) must be longer than
0.1ms when the voltage in PRB pin (VC) be-
comes higher than 0.3VDD after the voltage in
VDD pin exceeds 2.2V.
When the power on reset function is activated,
the standby state continues until an ²L² is in-
put to IE0~IE3.
0 .5 3 m s
1 .0 6 m s
0 .5 3 m s
H e a d p u ls e
C 0=0 C 1=1
C u s to m c o d e
C 2=1 C 3=0C 4=0C 5=0C 6=0C 7=0
B it " 0 "
2 .1 1 m s
Fig. 10
B it " 1 "
D a ta c o d e
D 0=0 D 1=0 D 2=0 D 3=0 D 4=1 D 5=0D 6=0 D 7=0
8 .4 4 m s
4 .2 2 m s
1 -w o rd
Fig. 11
4 .2 2 m s
1 w o rd
1 w o rd
6 7 .5 m s
Fig. 12
VSS
1
PRB 3
20 V D D
H T 6 2 4 0 -0 0 2
Fig. 13 Example of power-on reset function
V o lta g e
VDD
2 .2 V
V D D p in
P R B p in
0 .3 V D D
0
T im e
T C > 0 .1 m s
Fig. 14 Relationship between the PRB pin and
the voltage
9
December 16, 1999