datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

ZCA6C08I View Datasheet(PDF) - International Power DC Power Supplies

Part Name
Description
View to exact match
ZCA6C08I
International-Power-Sources
International Power DC Power Supplies International-Power-Sources
ZCA6C08I Datasheet PDF : 4 Pages
1 2 3 4
Configurable Power Supply
600 Watts
ZC Series
XPiQ inc.
Intelligent Design Quality Product
Meets EN61000-3-2, -3
Up to 5 Outputs Plus 5V Standby
Low Voltage Outputs Down to 1.8V
Hot Swap or Chassis Mount
Oring Diodes On All Outputs
(Hot Swap Modules)
1U, 19” Rack Mount for 2 units
International Safety Approvals with CE (LVD)
Specification
Input
AC Input Voltage
Input Frequency
DC Input Voltage
Power Factor
Harmonic Current
Inrush Current
Input Protection
• 85-264 VAC
• 47-63 Hz
• 48 VDC nominal (optional)
• 0.99
• Meets EN61000-3-2
• Limited to 30A peak
• Internal 15A fuse
Output
Output Voltage
Output Power
Output Voltage Adj •
Minimum Load
Line/Load Regulation •
Ripple & Noise
Transient Response •
Temperature Co-eff. •
Hold Up Time
Remote Sense
Overvoltage
Protection
Overcurrent
Protection
Overtemperature
Protection
Current Sharing
1.8 VDC to 12 VDC
600W
±5% min, See models chart
0 minimum load for all outputs
±2% for V1, V2 and V3, ±3%
for V4 and V5
>2.5V output: 50mV or 1% whichever
is greater <=2.5V output:
2% maximum
4% max deviation, 300 µs recovery
time for a 25% load change
0.02%/°C
20ms minimum
Up to 0.25 V compensation on V1, V2
and V3
V1, V2 and V3 only, recycle
input to reset
Standard with auto recovery
Logic high signal for overtemp
conditions
±10% for V1, V2 and V3 with
“H” option
General
Efficiency
Power Density
MTBF
Isolation Voltage
Signals
LED Indicators
Size
Weight
• 75% typical at full load
• 6.8 W/in3
• 200,000 hrs per Bellcore
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• PSU Enable, AC Fail, DC OK,
Global Inhibit, overtemp
• 2 status indicators
• 5.0” x 11.0” x 1.6”.
• 3.3 lbs (1.5 kgs.)
Environmental
Operating
Temperature
Cooling
Humidity
Storage Temperature •
0°C to 70°C, Full power to 50°C
derate from 50°C to 70°C
at 2.5%/°C
3 Internal ball bearing fans
<95% RH, non-condensing
-40°C to +85°C
Safety and EMC
Safety Approvals
• UL1950, CSA C22.2 No 950 per cUL,
EN60950 CE Mark LVD
EMI/EMC
• EN61000-3-2, -3, EN55022 and FCC
20780 part 15J Class B conducted
with rack, Class A stand alone
Immunity & Surge • Meets EN61000-4-4, -5
www.XPiQ.com
PH: 508 429.9883
FAX: 800 226.2100
Email: sales@xpiq.com
Holliston, MA 01746 USA

Share Link: 