datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

IN74ACT161 View Datasheet(PDF) - Integral Corp.

Part Name
Description
View to exact match
IN74ACT161 Datasheet PDF : 8 Pages
1 2 3 4 5 6 7 8
IN74ACT161
TIMING REQUIREMENTS (VCC=5.0V±10%, CL=50pF,Input tr=tf=3.0 ns)
Guaranteed Limit
Symbol
Parameter
+25° C
-40° C Unit
to +85° C
tSU Minimum Setup Time, Preset Data Inputs
9.5
to Clock (Figure 4)
11.5
ns
th Minimum Hold Time, Clock to Preset
0
Data Inputs (Figure 4)
0
ns
tSU Minimum Setup Time,Load to Clock
8.5
(Figure 4)
9.5
ns
th Minimum Hold Time, Clock to Load
-0.5
(Figure 4)
-0.5
ns
tSU Minimum Setup Time, Enable T or
5.5
Enable P to Clock (Figure 5)
6.5
ns
th Minimum Hold Time, Clock to Enable T
0
or Enable P (Figure 5)
0
ns
tw Minimum Pulse Width, Clock (Load)
3.0
(Figure 1)
3.5
ns
tw Minimum Pulse Width, Clock
3.0
(Count)(Figure 1)
3.5
ns
tw Minimum Pulse Width, Reset (Figure 2)
3.0
7.5
ns
trec Minimum Recovery Time, Reset to Clock
0
(Figure 2)
0.5
ns
5

Share Link: 