FlashFlex51 MCU
SST89E52RD2 / SST89E54RD2 / SST89E58RD2 / SST89E516RD2
SST89V52RD2 / SST89V54RD2 / SST89V58RD2 / SST89V516RD2
Preliminary Specifications
FFFFH
EA# = 0
EA# = 1
SFCF[1:0] = 00
FFFFH
EA# = 1
SFCF[1:0] = 01, 10, 11
FFFFH
External
64 KByte
56 KByte
Block 0
64 KByte
Block 0
FIGURE
2000H
0000H
1FFFH
0000H
8 KByte
Block 1
0000H
1255 F04.0
3-4: PROGRAM MEMORY ORGANIZATION FOR 64 KBYTE SST89E/V516RD2
3.2 Program Memory Block Switching
The program memory block switching feature of the device allows either Block 1 or the lowest 8 KByte of Block 0 to be
used for the lowest 8 KByte of the program address space. SFCF[1:0] controls program memory block switching.
TABLE 3-1: SFCF VALUES FOR PROGRAM MEMORY BLOCK SWITCHING FOR SST89E/V516RD2
SFCF[1:0]
01, 10, 11
00
Program Memory Block Switching
Block 1 is not visible to the program counter (PC).
Block 1 is reachable only via in-application programming from 0000H - 1FFFH.
Block 1 is overlaid onto the low 8K of the program address space; occupying address locations 0000H - 1FFFH.
When the PC falls within 0000H - 1FFFH, the instruction will be fetched from Block 1 instead of Block 0.
Outside of 0000H - 1FFFH, Block 0 is used. Locations 0000H - 1FFFH of Block 0 are reachable through
in-application programming.
T3-1.0 1255
TABLE 3-2: SFCF VALUES FOR PROGRAM MEMORY BLOCK SWITCHING FOR SST89E/V5XRD2
SFCF[1:0]
10, 11
01
00
Program Memory Block Switching
Block 1 is not visible to the PC;
Block 1 is reachable only via in-application programming from E000H - FFFFH.
Both Block 0 and Block 1 are visible to the PC.
Block 0 is occupied from 0000H - 7FFFH. Block 1 is occupied from E000H - FFFFH.
Block 1 is overlaid onto the low 8K of the program address space; occupying address locations 0000H - 1FFFH.
When the PC falls within 0000H - 1FFFH, the instruction will be fetched from Block 1 instead of Block 0.
Outside of 0000H - 1FFFH, Block 0 is used. Locations 0000H - 1FFFH of Block 0 are reachable through
in-application programming.
T3-2.0 1255
©2004 Silicon Storage Technology, Inc.
13
S71255-00-000
3/04