TFT-LCD DC-DC Converters with
Operational Amplifiers
Pin Description (continued)
NAME
PIN
MAX1516 MAX1517 MAX1518
FUNCTION
20
N.C.
N.C.
OUT5
Operational-Amplifier 5 Output. Not Internally Connected for the MAX1517 and
MAX1516.
21
LX
LX
LX
N-Channel Power MOSFET Drain and Switching Node. Connect the inductor and
Schottky diode to LX and minimize the trace area for lowest EMI.
22
IN
IN
IN
Supply Voltage Input. IN can range from 2.6V to 5.5V.
Step-Up Regulator Feedback Input. Regulates to 1.236V (nominal). Connect a resistive
23
FB
FB
FB
voltage-divider from the output (VMAIN) to FB to analog ground (AGND). Place the
divider within 5mm of FB.
Step-Up Regulator Error-Amplifier Compensation Point. Connect a series RC from
24
COMP
COMP
COMP COMP to AGND. See the Loop Compensation section for component selection
guidelines.
25
FBP
26
DRVP
27
FBN
28
DRVN
29
DEL
30
CTL
31
DRN
32
COM
FBP
DRVP
FBN
DRVN
DEL
CTL
DRN
COM
FBP
DRVP
FBN
DRVN
DEL
CTL
DRN
COM
Gate-On Linear-Regulator Feedback Input. FBP regulates to 1.25V (nominal). Connect
FBP to the center of a resistive voltage-divider between the regulator output and AGND
to set the gate-on linear-regulator output voltage. Place the resistive voltage-divider
close to the pin.
Gate-On Linear-Regulator Base Drive. Open drain of an internal n-channel MOSFET.
Connect DRVP to the base of an external pnp pass transistor. See the Pass-Transistor
Selection section.
Gate-Off Linear-Regulator Feedback Input. FBN regulates to 250mV (nominal).
Connect FBN to the center of a resistive voltage-divider between the regulator output
and REF to set the gate-off linear-regulator output voltage. Place the resistive voltage-
divider close to the pin.
Gate-Off Linear-Regulator Base Drive. Open drain of an internal p-channel MOSFET.
Connect DRVN to the base of an external npn pass transistor. See the Pass-Transistor
Selection section.
High-Voltage Switch Delay Input. Connect a capacitor from DEL to AGND to set the
high-voltage switch startup delay.
High-Voltage Switch Control Input. When CTL is high, the high-voltage switch between
COM and SRC is on and the high-voltage switch between COM and DRN is off. When
CTL is low, the high-voltage switch between COM and SRC is off and the high-voltage
switch between COM and DRN is on. CTL is inhibited by the undervoltage lockout and
when the voltage on DEL is less than 1.25V.
Switch Input. Drain of the internal high-voltage back-to-back p-channel MOSFETs
connected to COM.
Internal High-Voltage MOSFET Switch Common Terminal. Do not allow the voltage on
COM to exceed VSRC.