Rx ASIC
RF250
Table 3. Absolute Maximum Ratings
Parameter
Supply voltage (VCC)
Input voltage range
LNA input power
Power dissipation
Ambient operating temperature
Storage temperature
Minimum
–0.3
–0.3
--
--
–30
–40
Maximum
+5.5
VCC
+5
600
+80
+125
Units
V
V
dBm
mW
°C
°C
Table 4. Recommended Operating Conditions
Parameter
Supply voltage (VCC)
Operating temperature
Impedance of logic inputs
Logic 0
Logic 1
Min
2.7
–30
0.0
VCC – 0.5
Typical
3.3
+25
50
Max
3.6
+80
0.5
VCC
Units
V
°C
K
Ω
V
V