Digital Echo/Surround Processor IC
Tel: 886-2-66296288
Fax: 886-2-29174598
URL: http://www.princeton.com.tw
PT2396
MUTE FUNCTION
EASY MODE
Under the EASY Mode, the mute function is automatically activated under the following conditions:
1. Delay Time is changed.
2. SLEEP Mode is canceled.
3. Power is turned ON.
Condition 1: Automatic Mute Function Diagram 1 -- Delay Time Change
Condition 2: Automatic Mute Function Diagram 2 -- SLEEP Mode is canceled.
Condition 3: Automatic Mute Function Diagram 3 -- During Power ON
PT2396 V1.4
-8-
December, 2005