CY7C1041BV33
Maximum Ratings
(Above which the useful life may be impaired. For user guide-
lines, not tested.)
Storage Temperature ................................. –65°C to +150°C
Ambient Temperature with
Power Applied............................................. –55°C to +125°C
Supply Voltage on VCC to Relative GND[1] .... –0.5V to +4.6V
DC Voltage Applied to Outputs
in High Z State[1] ....................................–0.5V to VCC + 0.5V
DC Input Voltage[1] ................................ –0.5V to VCC + 0.5V
Current into Outputs (LOW) ........................................ 20 mA
Operating Range
Range
Commercial
Industrial
Ambient
Temperature[2]
0°C to +70°C
–40°C to +85°C
VCC
3.3V ± 0.3V
Electrical Characteristics Over the Operating Range
Parameter
Description
Test Conditions
VOH
Output HIGH Voltage
VCC = Min.,
IOH = –4.0 mA
VOL
Output LOW Voltage
VCC = Min.,
IOL = 8.0 mA
VIH
Input HIGH Voltage
VIL
Input LOW Voltage[1]
IIX
Input Load Current
GND < VI < VCC
IOZ
Output Leakage Current GND < VOUT < VCC, Output Disabled
ICC
VCC Operating
Supply Current
VCC = Max., f = fMAX = Comm’l
1/tRC
Ind’l
ISB1
Automatic CE
Max. VCC, CE > VIH
Power-Down Current
VIN > VIH or
—TTL Inputs
VIN < VIL, f = fMAX
ISB2
Automatic CE
Max. VCC,
Com’l/Ind’l
Power-Down Current
—CMOS Inputs
CE > VCC – 0.3V,
VIN > VCC – 0.3V,
Com’l L
or VIN < 0.3V, f = 0
-12
Min. Max.
2.4
0.4
2.2
VCC
+ 0.5
–0.5
0.8
–1
+1
–1
+1
190
-
40
8
0.5
-15
Min. Max. Unit
2.4
V
0.4
V
2.2
VCC
V
+ 0.5
–0.5
0.8
V
–1
+1
µA
–1
+1
µA
170 mA
190 mA
40 mA
8
mA
0.5 mA
Notes:
1. VIL (min.) = –2.0V for pulse durations of less than 20 ns.
2. TA is the “Instant On” case temperature.
Document #: 38-05168 Rev. **
Page 2 of 11